Warning: error_log(/home/sczxdq0srczzmxgdcq/wwwroot/en/caches/error_log.php) [function.error-log]: failed to open stream: Permission denied in /home/sczxdq0srczzmxgdcq/wwwroot/en/phpcms/libs/functions/global.func.php on line 449

Warning: error_log(/home/sczxdq0srczzmxgdcq/wwwroot/en/caches/error_log.php) [function.error-log]: failed to open stream: Permission denied in /home/sczxdq0srczzmxgdcq/wwwroot/en/phpcms/libs/functions/global.func.php on line 449

Warning: error_log(/home/sczxdq0srczzmxgdcq/wwwroot/en/caches/error_log.php) [function.error-log]: failed to open stream: Permission denied in /home/sczxdq0srczzmxgdcq/wwwroot/en/phpcms/libs/functions/global.func.php on line 449
Wind power transformer 2 - Wind power - 四川AG游戏官方网站電器有限公司
Product
phones: 15984311022
Contact: Lee
Address: Pengshan County, Meishan City, Sichuan Province
URL: www.sveun.com
Current position:HomePage > Product > Wind power >
Wind power transformer 2
Chinese name:Wind power transformer 2
English Name:
define :Wind power transformer 2
\
 
Brand: Netstar
Category: Wind power dry-type transformers,
690V/400V wind power wind power dedicated dry-type transformer dry-type transformers
Wind Power Transformer Features: · good insulation, partial discharge a small amount of resistance to lightning impulse capability. Wind towers can be placed inside or on top of the cabin. · Coil using a special process, enhance the anti-fog and anti-moisture capacity, improve operational reliability. All metal parts simultaneously reach C4 and above the level of corrosion, with a strong ability to adapt to the marine environment. · Low loss, low noise, small size, light weight, clean, maintenance-free, fire retardant, can be installed in the load center, saving the cost of investment.
Technical Specifications: * Implementation of the standards: IEC, GB, ANSI / IEEE, NEMA ·
Primary side rated voltage: 690V · Rated voltage secondary side: 400V
Frequency: 50/60 Hz
Phases: Three
Connection group: Dy11/Yd11
Insulation class: F / H
Rated temperature: 80K/100K/125K
Product Name: Wind power dry-type transformers SCB10
Product description:
Brand: Netstar
Category: Wind power dry-type transformers,
690V/400V wind power wind power dedicated dry-type transformer dry-type transformers
Wind Power Transformer Features: · good insulation, partial discharge a small amount of resistance to lightning impulse capability. Wind towers can be placed inside or on top of the cabin. · Coil using a special process, enhance the anti-fog and anti-moisture capacity, improve operational reliability. All metal parts simultaneously reach C4 and above the level of corrosion, with a strong ability to adapt to the marine environment. · Low loss, low noise, small size, light weight, clean, maintenance-free, fire retardant, can be installed in the load center, saving the cost of investment.
Technical Specifications: * Implementation of the standards: IEC, GB, ANSI / IEEE, NEMA ·
Primary side rated voltage: 690V · Rated voltage secondary side: 400V
Frequency: 50/60 Hz
Phases: Three
Wind Power Transformer Features: · good insulation, partial discharge a small amount of resistance to lightning impulse capability. Wind towers can be placed inside or on top of the cabin. · Coil using a special process, enhance the anti-fog and anti-moisture capacity, improve operational reliability. All metal parts simultaneously reach C4 and above the level of corrosion, with a strong ability to adapt to the marine environment. · Low loss, low noise, small size, light weight, clean, maintenance-free, fire retardant, can be installed in the load center, saving the cost of investment.
Technical Specifications: * Implementation of the standards: IEC, GB, ANSI / IEEE, NEMA ·
Primary side rated voltage: 690V · Rated voltage secondary side: 400V
Frequency: 50/60 Hz
Phases: Three